Connect for XML Converters not rejecting when GS06 does not Equal GE02

Information

 
TitleConnect for XML Converters not rejecting when GS06 does not Equal GE02
URL NameConnect-for-XML-Converters-not-rejecting-when-GS06-does-not-Equal-GE02
Article Number000128259
EnvironmentProduct: Connect for XML Converters
Version: 6.2
OS: Java
Database: Not applicable
Application: All supported applications
Question/Problem Description
Connect for XML Converters not rejecting when GS06 does not Equal GE02
Steps to Reproduce
Clarifying Information
When sending X12 EDI format document to analyze and the GS06 does not Equal GE02 a rejection response is not received. As per EDI X12 standards GS06 should be equal to GE02. 
 
Error Message
Defect Number
Enhancement Number
Cause
Resolution
By default Connect for XML Converters will auto-correct the GE02 if it's not filled in.
To change this behavior disable autofilling.

For additional information refer to the connect for XML Converters documentation, specifically the section titled "Autofilling Segments and Elements"
Workaround
Notes
References to other documentation:
DataDirect Driver Documentation, https://www.progress.com/documentation/datadirect-connectors
 
Last Modified Date10/22/2019 1:37 PM
Files
Disclaimer The origins of the information on this site may be internal or external to Progress Software Corporation (“Progress”). Progress Software Corporation makes all reasonable efforts to verify this information. However, the information provided is for your information only. Progress Software Corporation makes no explicit or implied claims to the validity of this information.

Any sample code provided on this site is not supported under any Progress support program or service. The sample code is provided on an "AS IS" basis. Progress makes no warranties, express or implied, and disclaims all implied warranties including, without limitation, the implied warranties of merchantability or of fitness for a particular purpose. The entire risk arising out of the use or performance of the sample code is borne by the user. In no event shall Progress, its employees, or anyone else involved in the creation, production, or delivery of the code be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss) arising out of the use of or inability to use the sample code, even if Progress has been advised of the possibility of such damages.