Feedback
Did this article resolve your question/issue?

   

Article

ErrorCode=3005, Internal error, fatal server error detected with OpenAccess SDK

Information

 
TitleErrorCode=3005, Internal error, fatal server error detected with OpenAccess SDK
URL NameErrorCode-3005-Internal-error-fatal-server-error-detected-with-OpenAccess-Java-SDK
Article Number000187933
EnvironmentProduct : OpenAccess SDK, SequeLink
Version : All supported versions
Database : NA
OS : All supported platforms
Application : All supported applications
Question/Problem Description
The below error is returned when starting OpenAccess SDK Server or SequeLink Server service
Steps to Reproduce
Clarifying Information
Error MessageProgress DataDirect OpenAccess SDK 7.2.0 - Server and IP SDK. Build 0050
hostname(2 CPU) - Linux(2.6.32-504.16.2.el6.x86_64-#1 SMP Tue Apr 21 08:37:59 PDT 2015)
ErrorCode=3005, Internal error, fatal server error detected. @srvc.swsrvc.c:2574: @SLSSL_DynInit
Shared Library Manager.SHLBGetEntryPoint:339(dlsym): ErrorCode=191, An error occurred in the shared library manager.
Defect Number
Enhancement Number
Cause
Resolution
Add the paths to the bin folders in front of the value of LD_LIBRARY_PATH.
When these are added at the end, there's a chance older libs are being picked up from an older OpenAccess version.
 
Workaround
Notes
Last Modified Date5/14/2018 9:04 PM
Files
Disclaimer The origins of the information on this site may be internal or external to Progress Software Corporation (“Progress”). Progress Software Corporation makes all reasonable efforts to verify this information. However, the information provided is for your information only. Progress Software Corporation makes no explicit or implied claims to the validity of this information.

Any sample code provided on this site is not supported under any Progress support program or service. The sample code is provided on an "AS IS" basis. Progress makes no warranties, express or implied, and disclaims all implied warranties including, without limitation, the implied warranties of merchantability or of fitness for a particular purpose. The entire risk arising out of the use or performance of the sample code is borne by the user. In no event shall Progress, its employees, or anyone else involved in the creation, production, or delivery of the code be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss) arising out of the use of or inability to use the sample code, even if Progress has been advised of the possibility of such damages.