SequeLink error "Internal error, fatal server error detected..SLSSL_DynInit"

Information

 
TitleSequeLink error "Internal error, fatal server error detected..SLSSL_DynInit"
URL NameSequeLink-error-Internal-error-fatal-server-error-detected-SLSSL-DynInit
Article Number000185709
EnvironmentProduct: SequeLink Server
Version: 6.0.0.16 and later
OS: All supported platforms
Database: All supported databases
Application: All supported applications
Question/Problem Description
SequeLink server fails to start and the error below is shown in the log.
Steps to Reproduce
Clarifying Information
Error MessageMon Mar 7 11:00:07 2016:lmbld1(2 CPU) - HP-UX(B.11.31-U)
Mon Mar 7 11:00:07 2016:SWANSRVC_SSLInit : openSSLPath='openssl600.so'
Mon Mar 7 11:00:07 2016:srvc.swsrvc.2028.Internal error, fatal server error detected..SLSSL_DynInit
Mon Mar 7 11:00:07 2016:Operating System.SHLBLoad.293(pathfind).2.No such file or directory
Defect Number
Enhancement Number
Cause
When the SequeLink product was enhanced to use OpenSSL version 1.0.0r, the OpenSSL library name changed.  The error occurs when the library cannot be read by the SequeLink service during startup.
Resolution
Make sure the library path includes the directory that contains openssl600.so.
Check to make sure the openssl600.so library permissions allow it to be read and executed by the SequeLink service.
Workaround
Notes
Last Modified Date6/1/2016 5:23 PM
Files
Disclaimer The origins of the information on this site may be internal or external to Progress Software Corporation (“Progress”). Progress Software Corporation makes all reasonable efforts to verify this information. However, the information provided is for your information only. Progress Software Corporation makes no explicit or implied claims to the validity of this information.

Any sample code provided on this site is not supported under any Progress support program or service. The sample code is provided on an "AS IS" basis. Progress makes no warranties, express or implied, and disclaims all implied warranties including, without limitation, the implied warranties of merchantability or of fitness for a particular purpose. The entire risk arising out of the use or performance of the sample code is borne by the user. In no event shall Progress, its employees, or anyone else involved in the creation, production, or delivery of the code be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss) arising out of the use of or inability to use the sample code, even if Progress has been advised of the possibility of such damages.