Article

"The specified DSN contains an architecture mismatch between the Driver and Application" error connecting with the SequeLink ODBC Socket Server with the MS Excel driver

Information

 
Title"The specified DSN contains an architecture mismatch between the Driver and Application" error connecting with the SequeLink ODBC Socket Server with the MS Excel driver
URL NameThe-specified-DSN-contains-an-architecture-mismatch-between-the-Driver-and-Application-error-connecting-with-the-SequeLink-ODBC-Socket-Server-with-the-MS-Excel-driver
Article Number000183479
EnvironmentProduct: SequeLink ODBC Socket Server
Version: 6.0
OS: Windows
Database: MS Excel
Application: Example
Question/Problem Description
The below error is observed connecting with the SequeLink ODBC Socket Server with the MS Excel driver
Steps to Reproduce
Clarifying Information
Error MessageSQLSTATE = IM014
NATIVE ERROR = 0
MSG = [DataDirect][ODBC 20101 driver][ODBC Socket]internal error: The specified DSN contains an architecture mismatch between the Driver and Application
Defect Number
Enhancement Number
Cause
The MS Excel driver is 32-bit but the SequeLink ODBC Socket Server is 64-bit.
Resolution
The bit version for the SequeLink ODBC Socket Server should match the backend MS Excel driver bit version which is 32-bit. 
Uninstalling the 64-bit SequeLink ODBC Socket Server and installing the 32-bit SequeLink ODBC Socket Server resolved the issue.
Workaround
Notes
Last Modified Date3/28/2016 6:02 PM
Files
Disclaimer The origins of the information on this site may be internal or external to Progress Software Corporation (“Progress”). Progress Software Corporation makes all reasonable efforts to verify this information. However, the information provided is for your information only. Progress Software Corporation makes no explicit or implied claims to the validity of this information.

Any sample code provided on this site is not supported under any Progress support program or service. The sample code is provided on an "AS IS" basis. Progress makes no warranties, express or implied, and disclaims all implied warranties including, without limitation, the implied warranties of merchantability or of fitness for a particular purpose. The entire risk arising out of the use or performance of the sample code is borne by the user. In no event shall Progress, its employees, or anyone else involved in the creation, production, or delivery of the code be liable for any damages whatsoever (including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss) arising out of the use of or inability to use the sample code, even if Progress has been advised of the possibility of such damages.